Nachrichten

Wie geht man mit einer Störung des industriellen Kaltwassersatzes um?
What's wrong with the Industrial Water Chiller System when it fails to cool down? Let LNEYA explain it to you below: One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with the installation of water-cooled chiller, cooling water tower, circulating water pump and pipe. It needs to be carefully checked according to the installation diagram. The second reason may due to the pipes which are attached to various devices for ...
Details anzeigen
Vocs exhaust gas condensation recovery unit refrigerant charging instructions
In the vocs exhaust gas condensation recovery process, the refrigerant is able to affect the operation of the vocs exhaust gas condensation recovery process, vocs exhaust gas condensation recovery treatment professional manufacturers reminded that in the case of the discovery of refrigerant loss, vocs exhaust gas condensation recovery treatment refrigerant charge Note work. Connect the vocs exhaust gas condensing and recycling various equipments. When vacuuming until the pressure drops to 133...
Details anzeigen
Über vocs Kondensationsadsorptionsmaschine Resonanzfehlerbeschreibung
When choosing vocs condensation adsorption machine, LNEYA recommends selecting reliable vocs condensation adsorption machine equipment to avoid some simple faults, but if a similar resonance fault occurs, it needs to be solved in time. For VOCS gas single material or multi-material condensation recovery, suitable for hydrocarbons: such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, styrene, stone brain Oils, etc.; alcoho...
Details anzeigen
Wie geht man mit Vereisung in kryogenen Kühlsystemen um?
If the low temperature refrigeration system has been frosted, believing that some enterprises have met, then how should we deal with such situation? Are there any methods can solve this problem. Today, let's know something about it with LNEYA refrigeration company. 1. First turn off the suction valve of the low temperature box compressor and unload to the minimum number of cylinders to operate. 2. Then close the liquid supply valve of the intermediate cooler and close the suction valve of the...
Details anzeigen
The maintenance and maintenance of an ultra-low temperature refrigerator
The maintenance and maintenance of an ultra-low temperature refrigerator are very important for normal usage and prolonging its life. If the inaccurate temperature control often results in the damage of the protected objects, which will greatly affect the experimental results, thus affecting the normal progress of the research work.1. Clean it once a month to ensure its cleanlinessRemove the dust on the inside and outside of the refrigerator and accessories by a dry cloth. If the refrigerator...
Details anzeigen
Prozessbeschreibung der LNEYA-Schraubenkühlmaschine
LNEYA screw chiller is suitable for all kinds of chemical, pharmaceutical, mechanical and other fields of production process cold source, can provide -25 ° C ~ 30 ° C chilled water, can be used as ice cold storage, low temperature air supply and other production processes required process cold source. LNEYA's screw chiller production specifications:1. Standard design conditions are: chilled water: effluent temperature 7 ° C, return water temperature 12 ° C; condensing temperature 30 ° C2. R...
Details anzeigen
Auswirkung und Lösung der Abgasübertemperatur von industriellen Kühlanlagen
Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chiller...
Details anzeigen
Das Kälteprinzip des LNEYA-Glykol-Kühlsystems
Glycol Chiller System SUNDI -10℃ ~ 200℃, as we can tell from its name, it is to use Glycol as the refrigeration agent for the chiller.In the all air environment, because of the low temperature in the outdoors, it is impossible to use a cooling tower to supply the inner area directly with the cold air-conditioner. In addition, the cold air in the outdoors could be used directly as refrigerator source,with glycol as refrigerant, it can introduce the natural cold air into the inner area and su...
Details anzeigen
5P Warm- und Kaltwassermaschine Installationsanleitung
The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibration reduction installation, or the vibration reduction effect is not good, according to the installation specifications, the overall vibration damping device should be installed. If the vibration reduction is not standardized or there is no vibration ...
Details anzeigen
Maintenance instructions for compressors at minus 85 degrees ultra low temperature freezer
The compressor in the ultra-low temperature freezer of minus 85 degrees is one of the main components, and its performance is very important, so maintenance is also very important. For manufacturers of sub-85 degree ultra-low temperature freezer compressor systems, the detection and replacement cycle of compressor refrigeration oil is related to the process control of its production. If the cleanliness control of the evaporator and condenser of the system and the system piping are better, the...
Details anzeigen