Suche im gesamten Bahnhof


News

Analysis of Common Faults in New Energy Vehicle...

Analysis of Common Faults in New Energy Vehicle Power Battery Test System

If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the body all connections (positive and negative lead, sampling line interface) . Close the maintenance switch assembly, multimeter test battery pack parameters: closed maintenance switch, use a multimeter to measure the total voltage of the power battery ...

Details anzeigen
New Energy Car Battery Test Equipment For Batte...

New Energy Car Battery Test Equipment For Battery Description

Lead-acid battery raw materials are easy to obtain, the price is relatively low, the high rate discharge performance is good, the temperature performance is good, can work in the environment of -40~+60 °C, suitable for float charging, long service life, no memory effect, used battery Easy to recycle, it is conducive to protecting the environment. However, the energy is low, generally 30~40Wh/kg, the service life is not as good as the Cd/Ni battery, and the manufacturing process is easy to pol...

Details anzeigen
How To Solve The Electric Vehicle Motor Test Co...

How To Solve The Electric Vehicle Motor Test Condensation Is Too High?

The condensing pressure of the electric vehicle motor test will increase, the compression function will increase, the cooling capacity will decrease, the cooling coefficient will decrease, and the energy consumption will increase. The reason for the rise of the condenser pressure may be that the condenser is too small. It is recommended to replace or increase the condensation. If the flow of cooling water is insufficient, it is recommended to increase the number of pumps running and increase ...

Details anzeigen
What Are The Characteristics Of The Reactor Hea...

What Are The Characteristics Of The Reactor Heating System?

Wuxi Guanya LNEYA reactor heating system The liquid circulation of the whole system is closed, the system has an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, only the mechanical connection, regardless of the temperature of the liquid circulation is high temperature Or the medium in the low temperature expansion vessel is below 60 degrees. The whole liquid circulation is a closed system. There is no water vapor a...

Details anzeigen
How To Choose The Equipment For The Reactor?

How To Choose The Equipment For The Reactor?

The choice of equipment for the reactor needs to be measured by the following points: 1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between. 2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 d...

Details anzeigen
Detailed Electric Vehicle Motor Test And Test S...

Detailed Electric Vehicle Motor Test And Test System

New energy vehicles need to have power system, drive system, control system integration test capability, and electronic electronic control test system function test capability. For component manufacturers, this test development capability is also the most important, electric vehicle. The motor test test items include general performance, environmental test, temperature rise test, motor torque characteristics and efficiency tests. The common motor test system for new energy vehicles has a dyna...

Details anzeigen
Effect Of Humidity On Laboratory Chillers

Effect Of Humidity On Laboratory Chillers

The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance of the electrical equipment, and the leakage current of the equipment is greatly increased, resulting in insulation breakdown. Condensation inside the switchgear causes creepage and flashover accidents, resulting in electrical faults. If the air is ...

Details anzeigen
Industrial Application Of Water-Cooled Chillers

Industrial Application Of Water-Cooled Chillers

Chillers, commonly known as freezers, chillers, chillers, chillers, chillers, etc., are widely used in various industries, so the names are numerous. The principle of its nature is a versatile cooling device that removes liquid vapor through a compression or heat absorption refrigeration cycle. The steam compression chiller consists of four main components of a vapor compression refrigeration cycle compressor, an evaporator, a condenser, and a partial metering device to achieve different refr...

Details anzeigen
Necessity Of New Energy Electric Vehicle Batter...

Necessity Of New Energy Electric Vehicle Battery Test System

The battery performance of new energy vehicles directly determines the experience of new energy vehicle end users. The electric vehicle battery test system needs to test the performance reliability of new energy vehicle batteries. With the development of technology, its requirements are also higher. . With the continuous development of new energy applications, the performance of power batteries for new energy vehicles has received extensive attention. Therefore, testing the ability to evaluat...

Details anzeigen

Relationship Between Poor Refrigeration Performance And Refrigerant In Low Temperature Industrial

The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are relatively low, and the expansion valve and the evaporator are in operation. The balance pressure cannot be maintained. Therefore, if the refrigerant leaks from the low-temperature industrial refrigerator (group) is found, it is not rushed to fill the sy...

Details anzeigen