Anwendungen:
Reactor kettle | Fermentation tank | Micro-reactor | Tubular reactor |
Vacuum chamber | Freeze-drying machine | Multiphase reactor | Aerospace Material Testing |
Petrochemical Treatment | Gas chromatograph | Rotary evaporator | Pilot plant |
Injection water system | Pharmaceutical water system | Neutralization reaction | Decomposition reaction |
oxidation reaction | Polymerization reaction | Crystallization reaction | Fermentation reaction |
Oil decomposition | Concentration reaction | Extraction System | Test Bench |
Gas Condensation | Semiconductor Testing equipment | Fab equipment | AOI system CMOS/CCD |
Tool machine | Bioreactor | Vehicle Testing | Laboratory research |

for reactors

for semiconductor test

for jacket reactor

for Laboratory research
Dynamic temperature control system has superior performance, high-precision, intelligent temperature control, and a very wide temperature control range, ranging from -120°C to 350°C, which is suitable for the constant temperature control needs of most enterprises.
Wir haben viele Modelle: SUNDI-Serie, WTD-Serie, KRY-Serie, LTS-Serie, etc. Die Temperaturregelungsgenauigkeit des Produkts kann ±0,1°C erreichen, und entsprechende Produkte können mit einer Kühlleistung von 0,5kW bis 1200kW angeboten werden.
Special note:
For SUNDI series water-cooled products with heating power ≤15kw, the condenser uses a plate heat exchanger and needs to use clean factory water. It is recommended to use a chiller or closed cooling tower for water supply.
(SUNDI series)
Temperaturregelbereich: -120°C bis +350°C
Dynamic control of cold and hot sources in reactors,temperature control accuracy can reach ±0.3℃
Temperaturbereich | SUNDI 320W | SUNDI -10℃~150℃ | SUNDI -25℃~300℃ | SUNDI -45℃~250℃ | SUNDI -60℃~250℃ | SUNDI -80℃~250℃ | SUNDI -90℃~250℃ | SUNDI -100℃~100℃ |
Kühlleistung | 2.1KW~15KW | 3.5KW~200KW | 2.5KW~200KW | 0.4KW~20KW | 2.5KW~60KW | 3KW~80KW | 5.5KW~20KW | 5.5KW~80KW |
Heizleistung | 3.5KW~15KW | 3.5KW~200KW | 0.25KW~200KW | 3.5KW~15KW | 0.25KW~60KW | 0.3KW~80KW | 0.5KW~80KW | 0.7KW~80KW |
Medium Temp Accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ |
Material Temp Accuracy | ±1℃ | ±0.1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
(WTD series)
(Mikrokanal / Röhrenreaktoren spezialisiert)
Temperaturregelbereich: -70°C bis +300°C
Spezielles Design für Mikrokanäle (geringe Flüssigkeitsspeicherkapazität, starke Wärmeaustauschkapazität, Zirkulationssystem mit hohem Druckabfall)
WTD Standard
* ,
WTD-2TE
Er wurde speziell für die Eigenschaften der kleinen Flüssigkeitsaufnahmekapazität, der starken Wärmeaustauschkapazität und des großen Druckabfalls im Zirkulationssystem des Mikrokanalreaktors konzipiert und entwickelt.
WTD-Doppelte Temperaturzone
Er wurde speziell für die Eigenschaften der kleinen Flüssigkeitsaufnahmekapazität, der starken Wärmeaustauschkapazität und des großen Druckabfalls im Zirkulationssystem des Mikrokanalreaktors konzipiert und entwickelt.
Laden...
已经是到最后一篇内容了!
((SUNDI Z Frequency Conversion series)
Temperature Control Range: -80°C to +250°C
Compared with SUNDI products, the refrigeration system and circulation system adopt frequency conversion control, which saves more than 20% energy, reduces noise by more than 5 decibels, and has a small starting current compared to the old products.
Temperaturbereich | SUNDI Z -45℃~250℃ | SUNDI Z -80℃~+250℃ |
Kühlleistung | 0.9KW~60KW | 0.4KW~20KW |
Heizleistung | 5.5KW~60KW | 3.5KW~15KW |
Medium Temp Accuracy | ±0.1℃ | ±0.1℃ |
Process Temp Accuracy | ±0.3℃ | ±0.3℃ |
Umwälzpumpen für Kühlung und Heizung
Temperaturregelbereich: -45°C bis +250°C
HR -25℃~200℃
The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A…
HRT -45℃~250℃
The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it’s blocked, then the temperature will go up. A main cause of t…
Laden...
已经是到最后一篇内容了!
TCU Temperatursteuergeräte
(Produktionsniveau in pharmazeutischen und chemischen Betrieben)
Temperaturregelbereich: -120°C bis +250°C
Anwendung: Chemische, pharmazeutische, petrochemische, biologische und andere Industriezweige, Anforderungen an die Temperaturregelung in der Großproduktion, wie z. B. verschiedene Reaktoren, Destillierapparate, Extraktionssysteme, Fermentationsbehälter usw. für Werkstätten im chinesischen Stil und die Produktion von pharmazeutischen und chemischen Anlagen.
TCS-Reihe
TCS integrated Reactor temperature control system First, advanced design conceptThis solution is based on the advanced process control system SIMATIC PCS 7 design. It refers to the advanced concept of real-time release testing in…
SR Series
TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infrastructure are integrated into the single fluid system was used to control the temperature o…
ZLF Series
Special temperature control system for reaction kettle -120~250℃ 士1°C TCU temperature control system USES the existing heat (such as steam, cooling water and cryogenic liquid – the “primary”) system infr…
Laden...
已经是到最后一篇内容了!
Modell | Heizleistung | Material Accuracy | Power Range | Power with”H” |
SR-Serie | 25kW~80kW | ±1℃ | 2.3kW~10.5kW | 27.3kW~90.5kW |
Baureihe ZLF | 25kW~80kW | ±1℃ | 2.3kW~10.5kW | 27.3kW~90.5kW |
Customized Cooling Heating Temperature Control System
Scan the QR code for consultation
E-Mail: sales@cnzlj.com
Vorteile
- Kühlleistung 0,5kW~1200kW
- Heizleistung 2kW~200kW
- Hochpräzise, intelligente Temperaturregelung
- Multifunktionales Alarmsystem und Sicherheitsfunktionen
- 7-Zoll- oder 10-Zoll-TFT-Farb-Touchscreen-Grafikdisplay
- Bei der Magnetkupplungspumpe gibt es kein Problem mit der Wellendichtung
- Hochtemperatur-Kühltechnologie, die direkt von 300°C herunterkühlen kann
- Effiziente Produktionsstabilität und reproduzierbare Ergebnisse
- Vollständig geschlossenes System, kein Austausch des flüssigen Mediums erforderlich




Working principle
Ein speziell entwickelter Lag-Schätzer (modellfreier Self-Building-Tree-Algorithmus) erzeugt ein dynamisches Signal yc(t) anstelle der Prozessvariablen y(t) als Rückkopplungssignal. Er erzeugt ein e(t)-Signal für den Regler, so dass der Regler keine große Hysterese bei der Vorhersage des Regeleffekts hat, so dass der Regler immer ein geeignetes Regelsignal erzeugen kann. Das heißt, dieses dynamische Signal yc(t) kann die Rückkopplungsschleife auch bei einer großen Verzögerung normal funktionieren lassen.

Anwendungen
- Dynamische Temperaturregelung eines Hochdruckreaktors
- Dynamische Temperaturregelung eines Zweischicht-Glasreaktors
- Dynamische Temperaturregelung eines Zweischichtreaktors
- Mikrokanal-Reaktor-Temperaturregelung
- Temperaturregelung des Destillationssystems
- Materialalterungstest bei niedriger und hoher Temperatur
- Kombinatorische chemische Konstanttemperaturregelung
- Kühlung und Heizung von Halbleiteranlagen
- Steuerung von Kühlung und Heizung der Vakuumkammer

1.Reactor 2.Vacuum chamber 3.Experimental instruments 4.Micro-channel

1.Semiconductor equipment 2.Mechanical assembly 3.Dryer 4.Evaporator

TCU installation site for integrated temperature control equipment of reaction kettle system in pharmaceutical enterprises

LNEYA’s industrial chiller cooling equipment is sold globally. Singapore, Malaysia, Japan, South Korea, various European countries, and the United States and other regions.

Low Temp/Normal Temp Chillers (Biochemistry Pharmaceutical Process)
Temperature Control :-5℃~-150℃
Temperature control for Various reactors, distillation or extraction systems, laboratories, research institutes, chemical, pharmaceutical, petrochemical, biochemical, medical, hospital, research and development workshops, semiconductor testing, aerospace, biology.
Control Temperature Control Flow Systems(Vehicle/Battery Pack Test)
Temperaturregelung: -40℃~100℃
Temperatur-Simulation for vehicle quality test:
für die Qualitätsprüfung von Fahrzeugen: Prüfung der Batterielebensdauer, Einspritzdüsen-/Motorprüfstand, Airbagtest, Komponentenprüfstand, usw. Es kann die externen Umweltbedingungen in der Klimakammer simulieren oder das interne System ersetzen, das die notwendigen tatsächlichen Temperaturbedingungen für den Prüfstand schaffen kann.
Kühlung-Heizung-Systeme (Halbleiterproduktion)
Temperaturregelung: -85℃~250℃
Suitable for semiconductor process wet washing, photolithography, etching, chemical meteorological deposition, physical meteorological deposition, and the electronics industry (photolithography process)
Customized Chiller Heater Combo Solutions